  • Controller based Design, Pure Sine Wave with 100% Tracking of Solar Panel,
  • Built in MPPT Solar Charge Controller.
  • Multi-Colour LCD Display.
  • All Parameter Selected.
  • Freq.:- Available – 50Hz & 60Hz.
  • Multi Charging Stage (Bulk, Absorption & Float)
  • Solar Priority of Load & Battery Charging.
  • Preference to Solar Power Over Grid Power.
  • Pure Sine Wave Output.
  • Protections : RBP, RSPV, OVL, BL, BH, S.Ckt, I/P HV& LV, OHT.
  • Compatible with DG as an Input Source.
  • Compatible with IT Load.
  • Compatible with Lithium, Gel & Tubular Batteries.
  • Priority Selection – PCU, Smart & Hybrid for Saving Energy and Money.
Add to Wishlist
Add to Wishlist
Categories: ,
Trust Badge Image

Description

Get two Battery back-up in Single Battery

  • Controller based Design, Pure Sine Wave with 100% Tracking of Solar Panel,
  • Built in MPPT Solar Charge Controller.
  • Multi-Colour LCD Display.
  • All Parameter Selected.
  • Freq.:- Available – 50Hz & 60Hz.
  • Multi Charging Stage (Bulk, Absorption & Float)
  • Solar Priority of Load & Battery Charging.
  • Preference to Solar Power Over Grid Power.
  • Pure Sine Wave Output.
  • Protections : RBP, RSPV, OVL, BL, BH, S.Ckt, I/P HV& LV, OHT.
  • Compatible with DG as an Input Source.
  • Compatible with IT Load.
  • Compatible with Lithium, Gel & Tubular Batteries.
  • Priority Selection – PCU, Smart & Hybrid for Saving Energy and Money.

Reviews

There are no reviews yet.

Be the first to review “Solar Home PCU – Tejas 2000VA-24V”

Your email address will not be published.

Specification

Parameters
Model TEJAS
Model  No. TEJAS 1200 TEJAS 2400
System Rating 1000VA 2000VA
Operating DC Voltage 12V 24V
Switching Element MOSFET
Charger Topology Boost Mosfet
Max. Battery Capacity 200AH
Operating Mode SMART/PCU/HYBRID Smart mode  (Default)
Optional DG mode Enable/Disable Disable (Default)
Parameters (Grid) Default Value Variable settable Range (Each Batt.)
Nominal Grid Voltage 230V 1Φ
Nominal frequency 50Hz
Frequency Range 47-53Hz + 1Hz
Battery Charging Method 3 Stages Bulk/Absorption/Float
Default charging mode TUB./Lithium Tubular
Grid – Battery Charging Voltage  (TUB) Boost 14.5V+0.2V  (Each Battery ) 13.5-15V
Float 13.8V+0.2V (Each Battery ) 13-14.2V
Grid – Battery Charging Voltage  (Lithium) Boost 14.0V+0.2V (Each Battery ) 13.5V-14.2V
Float 13.9V+0.2V  (Each Battery ) 13.4V-14.1V
Grid  Charging Current  Normal/Boost 10A/15A +2A 5A-15A
Optional Grid charging Enable/Disable Enable
Grid Reconnect @ Battery Voltage (TUB.) 11.8V +0.2V (Each Battery ) 11-12V
Grid Reconnect @ Battery Voltage (Lithium) 12.4V +0.2V (Each Battery ) NA
Grid Low Cut Voltage IT mode Enable 170V ± 10V
Grid Low Cut Recovery 180V ± 10V
Grid High Cut Voltage 265V ± 10V
Grid High Cut Recovery 255V ± 10V
Grid Low Cut Voltage IT mode Disable 100V ± 10V
Grid Low Cut Recovery 110V ± 10V
Grid High Cut Voltage 290V ± 10V
Grid High Cut Recovery 280V ± 10V
Change Over (Battery to Mains) IT mode Enable/Disable <8ms
Change Over (Mains to Battery) IT mode Enable <12ms
IT mode Disable <30ms
Parameters (Inverter)
Output Phase 1Φ
Nominal Output Voltage 220V
 Output voltage range 220V±8%
Nominal Frequency 50 Hz±1% 50Hz/60Hz
Max. Output Current 2.9A 5.6A
Battery Low Buzzer  (TUB.) 10.8V+0.2V (Each Battery )         Battery Low Cut- 0.3V
Battery Low Cut  (TUB.) 10.5V+0.2V (Each Battery ) 10-11.5V
Battery Low Buzzer  (Lithium) 11.9V+0.2V (Each Battery ) NA
Battery Low Cut  (Lithium ) 11.6V+0.2V (Each Battery ) NA
Battery High Cut (TUB.) 16.5+0.2V (Each Battery ) 16.5-17.5V
Battery High Cut (Lithium) 14.5+0.2V (Each Battery ) NA
Output Waveform Sinewave
Typical Efficiency >80% >82%
Voltage Harmonic <3%  (Linear Load)
Over Load Capacity IT Mode Disable >100%  After 30 sec delay (with alarm) 3Time Auto Reset , 4th Time Shut Down

Note : 1HP Motor Load Run for 15min with alarm (1 Sec ON, 5 Sec OFF) in 2400 Model .

IT Mode Enable >100% After 30 sec delay (with Alarm) 1st Time Shut Down
>150% Output Goes Down
Motor 1 HP NA Yes (<6.5A)
Protection Overload, Battery Low, Battery High, Output Short Ckt, Battery Reverse (Fuse Blown) , Over Heat @90*C ± 10*C, Over/Under frequency, I/P HV, I/P LV, SPV High, SPV Low
LED Indication System ON, (IT mode, TUB/Lithium , Boost Chg, DG mode, Grid Chg.)Enable/Disable
Switches (Micro)  Reset for System ON/OFF, UP, Down, Back, Enter (For LCD Calibration)
Display  ( Multi color) Battery Voltage, Charging Current, Grid Voltage, Grid Frequency, Output Voltage, Output Frequency, Load %, Battery Graph, Overheat, SPV Current, Operating Mode (HYB/PCU/SMT)
Parameters (Solar)
Switching Element Mosfet
Type of Charger MPPT
SPV Chgarging Voltage (TUB) Boost 15V+0.2V (Each Battery ) 14-15.5V
Float 14.2V+0.2V (Each Battery ) 13.8-14.5V
SPV Charging Voltage (Lithium) Boost 14.2V+0.2V (Each Battery ) 14.0-14.4V
Float 14.1V+0.2V (Each Battery ) 13.5-14.2V
SPV Charging Current 18A+2A 11-40A
Battery Charging Method 3 Stages Bulk/Absorption/Float
Efficiency >94%
Input Voltage Range (Min, – Max) Voc 15V-49.5V  30V-99V
Maximum PV Power Recommended 1000W  2000W
Parameters (Environment)
Operating Temperature 0-50°C
Cooling  Fan
Max. Relative Humidity @ 25*C (Non Condensing) 95%
Noise @ 1 meter 50dB
Standard Compliance IP20
System Weight (KG) 12.4 17.6
Dimension (LXWXH)mm  327.8 X305.5 X 116 333.8 X 305.5 X 158.6